The durability test of connecting wires can be simplified into three modules: "mechanical environment electrical", which can be executed in the following order:
Mechanical durability
• Bending life: ± 90, R=5 mm, no breakage after reciprocating ≥ 1000 times
• Plug and unplug cycle: The connector is repeatedly plugged and unplugged ≥ 750 times, and the contact resistance changes ≤ 50 m Ω
Vibration impact: 10-500 Hz, acceleration of 20 g, continuous for 24 hours without looseness
Environmental durability
• Temperature cycle: -40 ° C ↔ + 85 C 500 cycles, no cracks in appearance, resistance change ≤ 5%
High temperature aging: insulation does not become brittle at 105 ° C for 1000 hours, and the increase in conductor resistance is ≤ 5%
Damp heat/salt spray: 95% RH for 168 hours or salt spray for 96 hours, with no rust on the surface
Electrical durability
• Insulation resistance: ≥ 500 M Ω (still meets the standard after testing)
• Voltage resistance: 1500 V AC for 60 seconds without breakdown
Signal attenuation: 100 MHz attenuation ≤ 20 dB (still qualified after bending/aging)